Feautures :

Memory capacity is 8100 lines of data per channel. (It is possible to store data for about 506 days with log interval of 90 minutes and about 168 days with log interval of 30 minutes.)

The method of storing data can be selectable among four logging options : Once (default), Repeatability (overwriting), Ends at (limited amount), By page (partitioning).

The software for data analysis and realtime transmission is attached as standard accessories.

The date and time to start logging automatically can be specified by setting the preset start.

The measurement data can be transmitted in realtime to a personal computer.

USB transmission is adopted .

The upper and lower thresholds for warning can be set. When the temperature or humidity threshold is triggered, the alarm mark (Hi or Lo) will light.

Probes are interchangeably used with main units.

The storage memory can be verified with the memory indicator.

The log interval can be selected from 14 options: 1 sec, 2 sec, 5 sec, 10 sec, 15 sec, 30 sec, 1 min, 2 min, 5 min, 10 min, 15 min, 30 min, 60 min. and 90 min.

When the power is turned off, data stored in the EEPROM memory is retained.

The datalogger ID can be set. This is useful to identify multiple dataloggers.

By using data analysis software attached, acquired data can be evaluated easily and quickly, and also evaluated by using commercial spreadsheet software supporting the "CSV" extension such as Lotus 1-2-3 and Microsoft Excel.

 

Model SK-L200THII α (temperature and humidity measurement type)
Display range -15 to 65.0°C (depending on a probe connected)
10 to 99.9% rh
Resolution(Temp.) 0.1°C at -9.9 to 65.0°C
1°C at -10°C or less
Resolution(Hum.) 0.1% rh at 15.0 to 99.9% rh
1%rh at less than 15.0%
Accuracy (Temp) ±(0.1°C + 1 digit)
Accuracy (Hum.) ±(0.1% rh + 1 digit)
Probes connected SK-LTHII α series probes
Sampling (display) about 1 sec.
Display functions TIME (display time), INT (log interval) REC (during logging), RES (during preset standby), OUT (during real-time transmission), LCD bars (used memory)
CALL (call for the current measurement data during logging)
Current temperature, Current humidity, Current date and time, low battery symbol, Temp. upper limit (Hi), Temp. lower limit (Lo), Hum. upper limit (Hi), Hum. lower limit (Lo), Temp. alarm ON (Alarm), Hum. alarm ON (Alarm), logging option, setting value of upper and lower limits, error message, ID number
Memory capacity 8100 lines of data, but depending on the logging option
(four logging potions: Once, Repeatability, Ends at, By page)
Log interval 1 sec., 2 sec., 5 sec., 10 sec., 15 sec., 30 sec.
1 min., 2 min.,5 mi.,10 min., 15 min., 30 min., 60 min., 90 min.
Communication USB
Operation ambient -10 to 60°C, no condensing
Storage ambient 0 to 50°C
Power requirement "AAA" size Alkaline battery x 2
Battery life . Under continuous measurement mode : more than 500 hours
. Under logging mode: possible to log 8100 data with every log interval
(ex.: about 506 days with log interval of 90 minutes.)
Dimensions (W) 100 x (H) 73 x (D) 22 mm
Weighs about 123 g (exclusive of batteries)
Materials ABS resin
Accessories CD-Rom (Data analysis and realtime software), USB cable (1.5 m) , USB port cap (factory set), hand strap, "AAA" battery x 2